ISO 9001:2015 Certified
Live Customer Support
4.5/5 on Trustpilot
100% Quality Guarantee

Human Myelin Oligodendrocyte Glycoprotein Autoantibody ELISA Kit (A326737)

$640

Shipping Information

$40
Dispatched from St. Louis, MO.
Lead Time: 7-11 business days.
Name
Human Myelin Oligodendrocyte Glycoprotein Autoantibody ELISA Kit
Description
Human Myelin Oligodendrocyte Glycoprotein Autoantibody ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Myelin Oligodendrocyte Glycoprotein Autoantibody in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.
Assay Type
Sandwich (quantitative)
Principle of Assay
Human Myelin Oligodendrocyte Glycoprotein Autoantibody ELISA Kit (A326737) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human Myelin Oligodendrocyte Glycoprotein Autoantibody in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples. An antibody specific for Myelin Oligodendrocyte Glycoprotein Autoantibody has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the Myelin Oligodendrocyte Glycoprotein Autoantibody present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-Myelin Oligodendrocyte Glycoprotein Autoantibody Antibody, which binds the captured Myelin Oligodendrocyte Glycoprotein Autoantibody present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of Myelin Oligodendrocyte Glycoprotein Autoantibody captured in each well. The concentration of Myelin Oligodendrocyte Glycoprotein Autoantibody can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.
Platform
Pre-coated Microplate (12 x 8 well strips)
Detection Type
Colorimetric
Instrument
Colorimetric Microplate Reader
Sample Type
Serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.
Sensitivity
0.938 ng/ml
Product Range
1.563-100 ng/ml
Assay Time
3 hours
Reactivity
Human
Recovery
Sample Type n Range Average
Serum 10 86% - 105% 96%
EDTA Plasma 10 92% - 103% 98%
Heparin Plasma 10 90% - 99% 95%
Linearity
Sample Type n 1:2 1:4 1:8
Serum 10 86-104% 86-101% 86-98%
EDTA Plasma 10 87-100% 88-99% 89-99%
Heparin Plasma 10 86-103% 90-98% 85-94%
Precision
Intra-assay CV: < 8%, Inter-assay CV: < 10%
Storage
Store at +4°C. Do not use past expiration date!
Product Note
Information online is representative. Always refer to the Product Manual inside the kit.
Disclaimer
This product is for research use only. It is not intended for diagnostic or therapeutic use.
Publishing research using Human Myelin Oligodendrocyte Glycoprotein Autoantibody ELISA Kit (A326737)? Please let us know so that we can list the citation on this page.