ISO 9001:2015 Certified
Live Customer Support
4.5/5 on Trustpilot
100% Quality Guarantee

Human TMEM127 ELISA Kit (A75076)

Shipping Information

$40
Dispatched from St. Louis, MO.
Lead Time: 7-11 business days.
Name
Human TMEM127 ELISA Kit
Description
Human TMEM127 ELISA Kit is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human TMEM127 in serum, plasma, tissue homogenates, and other biological fluids.
Assay Type
Sandwich (quantitative)
Principle of Assay
Human TMEM127 ELISA Kit (A75076) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human TMEM127 in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for TMEM127. Standards and samples are added to the wells, where TMEM127 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for TMEM127 is added to the wells. The detection antibody binds the captured TMEM127 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of TMEM127 captured in each well. The concentration of TMEM127 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.
Platform
Pre-coated Microplate (12 x 8 well strips)
Detection Type
Colorimetric Detection (OD450)
Instrument
Colorimetric Microplate Reader
Sample Type
Serum, plasma, tissue homogenates, and other biological fluids.
Sensitivity
46.875 pg/mL
Product Range
78.125-5000 pg/mL
Assay Time
4 hours
Reactivity
Human
Cross Reactivity
Specific for TMEM127 with no reported cross-reactivity with other analogs or variants.
Recovery
Sample Type n Range Average
Serum 10 86% - 102% 94%
EDTA Plasma 10 86% - 98% 93%
Heparin Plasma 10 89% - 104% 97%
Linearity
Sample Type n 1:2 1:4 1:8
Serum 10 97-105% 87-104% 90-102%
EDTA Plasma 10 84-92% 89-99% 82-100%
Heparin Plasma 10 82-95% 80-98% 80-96%
Storage
Shipped at +4°C. Store kit components at +4°C or -20°C as instructed in the Protocol Manual. Do not use past expiration date! Avoid freeze/thaw cycles.
Synonyms
Transmembrane protein 127
Product Note
Information online is representative. Always refer to the Product Manual inside the kit.
Disclaimer
This product is for research use only. It is not intended for diagnostic or therapeutic use.
Publishing research using Human TMEM127 ELISA Kit (A75076)? Please let us know so that we can list the citation on this page.

Proteins predicted to interact with TMEM127

Predicted protein interactions based upon String database. Revelancy score correlates with probability of interaction.
96% Relevancy Score
93.4% Relevancy Score
90.5% Relevancy Score
90.3% Relevancy Score
88.3% Relevancy Score
80.7% Relevancy Score
76.8% Relevancy Score
67.2% Relevancy Score
64.7% Relevancy Score