ISO 9001:2015 Certified
Live Customer Support
4.5/5 on Trustpilot
100% Quality Guarantee

Mouse CD48 ELISA Kit (Small Sample Volume) (A351775)

$395

Shipping Information

$40
Dispatched from St. Louis, MO.
Lead Time: 8-12 business days.
Name
Mouse CD48 ELISA Kit (Small Sample Volume)
Description
Mouse CD48 ELISA Kit (Small Sample Volume) is a 3h 30m sandwich Enzyme-Linked Immunosorbent Assay (sELISA) optimized for small sample volumes requiring only 25 µL of sample, designed for the in vitro quantitative determination of mouse CD48 in serum, plasma, and other biological fluids.
Assay Type
Sandwich (quantitative)
Principle of Assay
Mouse CD48 ELISA Kit (Small Sample Volume) (A351775) employs the sandwich Enzyme-Linked Immunoassay technique for the quantitative measurement of mouse in serum, plasma, and other biological fluids. This assay is optimized for limited sample availability, requiring only 25 µL of sample per well. An antibody specific for CD48 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the CD48 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with biotinylated anti-CD48 antibody, which binds the captured CD48 present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of CD48 captured in each well. The concentration of CD48 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.
Components
Pre-Coated 96 Well Microplate, Reference Standard, Biotinylated Detection Antibody, Concentrated Biotinylated Detection Antibody, HRP Conjugate, Concentrated HRP Conjugate, Reference Standard & Sample Diluent, Biotinylated Detection Antibody Diluent, HRP Conjugate Diluent, Wash Buffer (25X), TMB Substrate, Stop Solution, Plate Sealers, Product Manual.
Platform
Pre-coated Microplate (12 x 8 well strips)
Detection Type
Colorimetric Detection (OD450)
Instrument
Colorimetric Microplate Reader
Sample Type
Serum, plasma, and other biological fluids.
Sensitivity
14.06 pg/mL
Product Range
23.44-1500 pg/mL
Assay Time
3h 30m
Reactivity
Mouse
Cross Reactivity
Specific for CD48 with no reported cross-reactivity with other analogs or variants.
Recovery
Sample Type n Range Average
Serum 8 83-95% 90%
EDTA Plasma 8 87-100% 93%
Cell Culture Media 8 85-98% 92%
General Notes
Information online is representative. Always refer to the Product Manual inside the kit.
Storage
Store kit components at +4°C or -20°C as instructed. Do not use past expiration date!
Synonyms
B-lymphocyte activation marker BLAST-1, BCM1, BCM1 surface antigen, BLAST1, CD48 antigen, Leukocyte antigen MEM-102, Signaling lymphocytic activation molecule 2, SLAM family member 2, SLAMF2, TCT.1
Product Note
Information online is representative. Always refer to the Product Manual inside the kit.
Disclaimer
This product is for research use only. It is not intended for diagnostic or therapeutic use.
Publishing research using Mouse CD48 ELISA Kit (Small Sample Volume) (A351775)? Please let us know so that we can list the citation on this page.

Proteins predicted to interact with CD48

Predicted protein interactions based upon String database. Revelancy score correlates with probability of interaction.
99.9% Relevancy Score
99.8% Relevancy Score
95.7% Relevancy Score
94.8% Relevancy Score
90.9% Relevancy Score
90.3% Relevancy Score
89.1% Relevancy Score
85.3% Relevancy Score
83.8% Relevancy Score