Human peripheral blood mononuclear cells (PBMCs), CCRF-CEM, and HL-60 cells.
Dilutions
Flow Cytometry: 5 µL/million cells in 100 µL.
Reactivity
Human
Immunogen
Human peripheral blood T cells.
Host
Mouse
Clonality
Monoclonal
Clone ID
SK3
Isotype
IgG1
Light Chains
kappa
Conjugate
APC
Excitation: 645nm, Emission: 660nm
Concentration
50 µg/mL
Predicted MW
55 kDa
Product Form
Liquid
Formulation
Supplied in Phosphate Buffered Saline with 0.1% BSA and 0.05% Sodium Azide.
Storage
Shipped and stored at +4°C. This product is also photosensitive and should be protected from light. Should this product contain a precipitate we recommend microcentrifugation before use. This CF® conjugated antibody is guaranteed for 2 years from data of receipt when stored correctly.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®700) (teal). Fluorescence was detected in the R712 (APC-700) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®405M) (blue). Fluorescence was detected in the V450 (Pacific Blue) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®405S) (blue). Fluorescence was detected in the V450 (Pacific Blue) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®405L) (green). Fluorescence was detected in the V525 (FITC) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®488A) (green). Fluorescence was detected in the B525 (FITC) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®503R) (green). Fluorescence was detected in the B525 (FITC) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®514) (green). Fluorescence was detected in the B525 (FITC) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Representative flow cytometry analysis of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (R-PE) ( Orange). Unstained lymphocyte-gated PBMCs (gray) served as the negative control. Fluorescence was detected in the Y585 (PE) channel.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®568) (orange). Fluorescence was detected in the Y585 (PE) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®575) (orange). Fluorescence was detected in the Y585 (PE) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (RPE-Astral™616) (red). Fluorescence was detected in the B610 (PI) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®647Plus) (pink). Fluorescence was detected in the R660 (APC) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®660C) (pink). Fluorescence was detected in the R712 channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (APC) (pink). Fluorescence was detected in the R660 (APC) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (APC-Astral™813) (teal). Fluorescence was detected in the R840 channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®700) (teal). Fluorescence was detected in the R712 (APC-700) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®820) (teal). Fluorescence was detected in the IR840 channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (PerCP) (magenta). Fluorescence was detected in the B690 (PerCP) channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (RPE-Astral™775) (teal). Fluorescence was detected in the Y763 channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Flow cytometry of lymphocyte-gated PBMCs stained with Anti-CD4 Antibody [SK3] (CF®870) (teal). Fluorescence was detected in the IR885 channel. Unstained lymphocyte-gated PBMCs (gray) is shown for comparison.
Immunofluorescence staining of 6×His-tagged CD4 in HeLa cells transiently transfected with a CD4-6×His expression vector. Following fixation with 4% paraformaldehyde (PFA), cells were stained with Anti-CD4 Antibody [SK3] (CF®488A; green) and Anti-His Tag Antibody [2405.H6] (CF®680; magenta). Nuclei were counterstained with Hoechst 33342 (blue). Images were acquired by confocal microscopy.