ISO 9001:2015 Certified
Live Customer Support
4.5/5 on Trustpilot
100% Quality Guarantee

Human Angiotensin II Type 1 Receptor Antibody ELISA Kit (A73861)

$665

Shipping Information

$40
Dispatched from St. Louis, MO.
Lead Time: 7-11 business days.
Name
Human Angiotensin II Type 1 Receptor Antibody ELISA Kit
Description
Human Angiotensin II Type 1 Receptor Antibody ELISA Kit is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Angiotensin II Type 1 Receptor Antibody in serum, plasma, tissue homogenates, and other biological fluids.
Assay Type
Sandwich (quantitative)
Principle of Assay
Human Angiotensin II Type 1 Receptor Antibody ELISA Kit (A73861) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Angiotensin II Type 1 Receptor Antibody in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with assay-specific antigen. Standards and samples are added to the wells, where Angiotensin II Type 1 Receptor Antibody binds to the immobilized antigen. Following incubation, unbound components are removed by washing and a biotinylated antigen detection reagent is added to the wells. This reagent binds the captured Angiotensin II Type 1 Receptor Antibody to form an antigen-antibody-antigen sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of Angiotensin II Type 1 Receptor Antibody captured in each well. The concentration of Angiotensin II Type 1 Receptor Antibody is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.
Platform
Pre-coated Microplate (12 x 8 well strips)
Detection Type
Colorimetric Detection (OD450)
Instrument
Colorimetric Microplate Reader
Sample Type
Serum, plasma, tissue homogenates, and other biological fluids.
Sensitivity
1.875 ng/mL
Product Range
3.125-200 ng/mL
Assay Time
4 hours
Reactivity
Human
Cross Reactivity
Demonstrates specificity for Angiotensin II Type 1 Receptor antibodies with no reported cross-reactivity to related analogs.
Recovery
Sample Type n Range Average
Serum 10 96% - 104% 99%
EDTA Plasma 10 96% - 105% 100%
Heparin Plasma 10 96% - 104% 100%
Linearity
Sample Type n 1:2 1:4 1:8
Serum 10 95-105% 91-97% 90-98%
EDTA Plasma 10 92-103% 96-101% 91-99%
Heparin Plasma 10 93-105% 89-99% 91-97%
Storage
Shipped at +4°C. Store kit components at +4°C or -20°C as instructed in the Protocol Manual. Do not use past expiration date! Avoid freeze/thaw cycles.
Product Note
Information online is representative. Always refer to the Product Manual inside the kit.
Disclaimer
This product is for research use only. It is not intended for diagnostic or therapeutic use.
Publishing research using Human Angiotensin II Type 1 Receptor Antibody ELISA Kit (A73861)? Please let us know so that we can list the citation on this page.