Warning: mysqli::query(): (HY000/1206): The total number of locks exceeds the lock table size in D:\wwwroot_antibodies\system\library\db\mysqli.php on line 20Notice: Error: The total number of locks exceeds the lock table size
Error No: 1206
SELECT distinct mt2.maintarget, mt2.human_uniprot, spl.protein_codeb, spl.score, spi.protein_detail, mt2.url FROM oc_maintarget mt1, oc_string_protein_links spl, oc_string_protein_info spi, oc_maintarget mt2, oc_product_description pd WHERE mt1.maintarget = 'GM-CSF' AND spl.protein_codea = mt1.string_protein_code AND spi.protein_code = spl.protein_codeb AND mt2.string_protein_code = spi.protein_code and pd.maintarget = mt2.maintarget and pd.category = 'ELISA Kits' and pd.status = 1 and pd.uk_min_price > 0 ORDER BY spl.score DESC LIMIT 9 in D:\wwwroot_antibodies\system\library\db\mysqli.php on line 42Notice: Trying to get property 'num_rows' of non-object in D:\wwwroot_antibodies\catalog2\model\catalog\product.php on line 1832 Human GM-CSF ELISA Kit (A117488)
ISO 9001:2015 Certified
Live Customer Support
4.5/5 on Trustpilot
100% Quality Guarantee

Human GM-CSF ELISA Kit (A117488)

Shipping Information

$40
Dispatched from St. Louis, MO.
Lead Time: 7-10 business days.
Name
Human GM-CSF ELISA Kit
Description
Human GM-CSF ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human GM-CSF in serum, plasma and cell culture supernates.
Assay Type
Sandwich (quantitative)
Principle of Assay
Human GM-CSF ELISA Kit (A117488) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human GM-CSF in serum, plasma and cell culture supernates. An antibody specific for GM-CSF has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the GM-CSF present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-GM-CSF Antibody, which binds the captured GM-CSF present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of GM-CSF captured in each well. The concentration of GM-CSF can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.
Platform
Pre-coated Microplate (12 x 8 well strips)
Detection Type
Colorimetric
Instrument
Colorimetric Microplate Reader
Sample Type
Serum, plasma and cell culture supernates.
Sensitivity
7.8 pg/ml
Product Range
7.8-500 pg/ml
Assay Time
4 hours
Sample Size
100µl
Reactivity
Human
Precision
Intra-assay CV: <3.2%, Inter-assay CV: <6.7%.
General Notes
Information online is representative. Always refer to the Product Manual inside the kit. This ELISA kits uses Anti-GM-CSF Antibody (A329407) as the capture antibody and Anti-GM-CSF Antibody (A329408) as the detection antibody.
Storage
Shipped at 4°C. Unopened kits can be stored at +4°C for 12 months. Once opened products must be used within 1 month.
Synonyms
Colony-stimulating factor, CSF, CSF2, GMCSF, Granulocyte-macrophage colony-stimulating factor, Molgramostin, Sargramostim
Product Note
Information online is representative. Always refer to the Product Manual inside the kit.
Disclaimer
This product is for research use only. It is not intended for diagnostic or therapeutic use.
Publishing research using Human GM-CSF ELISA Kit (A117488)? Please let us know so that we can list the citation on this page.

Alternative products to Human GM-CSF ELISA Kit (A117488)